Commit 8655ea1b authored by Daniel Brown's avatar Daniel Brown

Noting frequency dependent R and T settings now

parent 7f9d4a02
......@@ -62,6 +62,25 @@ added features:
Specify how many homodyne measurements you need, and a transfer function to scale the output
of each before combining them.
o Frequency selective R and T at a beamsplitter. You can now set the R and T value for a given
frequency bin. This is set by the frequency name which can be found by running the file with
using the `frequency` command. This will print a list of all frequencies and their names.
With this name you can then set the R and T value as shown below:
Example: Reflecting the lower (minus) sideband
l l1 1.0 0 0.0 n1
bs bs1 1 0 0 0 n1 n2 n3 n4
# conf beamsplitter fRT frequency_name R T
conf bs1 fRT l1_psb 0 1
conf bs1 fRT l1_msb 1 0
fsig sig l1 1 0 1
ad u $fs n3
ad l $mfs n3
bug fixes:
o noxaxis no longer tries to call gnuplot/python plotting
......
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment