Saturating ETMX L3 at states between 100-500
I thought we had solved this problem by dividing the 20-bit ETMX L3 channel outputs by 4, but it seems that in a large number of states, all ETMX L3 channels are well above the saturation limit for the entire 150 second duration before the lockloss. I will look into the saturations followup first and then probably check the actual ETMX L3 values.
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1251066589
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1250743211
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1250913231
Edited by Yannick Lecoeuche