limits on length pitch yaw saturation plots
can we set the limits on the length pitch yaw plots in a way similar to how they are set for the "Saturation plots"?
Although we should set it to 4 times the threshold that is used for saturating an individual coil, since each of these signals can be sent to multiple coils. Most of the time this will work fine, there are a few examples where settings the limits to 4 wouldn't be the right things to do (if the top mass is saturating) but that doesn't come up very often and I think that we can rely on people be able to interpret those rare cases correctly. (What I mean to say is let's not get caught up on that detail).