gps end time in .err output
Noticed that the output of the .err file say something like
Estimating PSD for L1 using 1 segments of 4096 samples (4.000000s)
Slid PSD estimation of L1 by -0.000000 s from 1240164424.1396000385 to 1240164424.1396000385
If I am not wrong the end time of the .err file is wrong, since it is equal to the start time. The start-time though it is correct.
I have checked others run. But if you want to crosscheck this one,
it is a single detector running at
CIT/home/nicola.delillo/projects/O3/PE/S190424ao/bayeswave/C01_L1_4s_S190424ao/logs
.
The .ini and pipe command can be found here /home/nicola.delillo/projects/O3/PE/S190424ao/bayeswave
.
Not sure if this is supposed to be like it is now. Please close this issue if it is not a bug.