Infinite LogL and LogZ for ingested PSDs
If BayesWave ingests a pre-computed PSD from file which ends before Nyquist, the printed LogL and LogZ values are infinite. E.g., if the Nyquist frequency is 512 Hz but the PSD file only goes to 511 Hz, we get things like:
$ cat trigtime_1238782700.288180113_0.0_0.0_0/evidence.dat
signal -inf -nan
Reconstructions (and waveform moments) look ok so presumably the internal likelihood values are fine (and published reconstruction results are ok..). Also note that the logL printed to stdout looks ok. Just not the logL printed to the results file.
Examples can be found in the O3a catalog runs (CIT:/home/sudarshan.ghonge/Projects/O3a/C01_runs
) and re-runs for profiling studies (e.g. CIT:/home/james.clark/Projects/bayeswave-job-profiling/o3a-catalog-events/S190408an_nocheckpoint
, and friends)