... | ... | @@ -95,6 +95,18 @@ After some bugs were identified, a rerun of the millilensing run has yielded the |
|
|
- [Signal 1 Phase](https://ldas-jobs.ligo.caltech.edu/\~mick.wright/gravelamps-o4-review/milli-discrete-phase-1.png)
|
|
|
- Parameters are largely as expected, signal 1 phase may bear some further investigation since it does not seem to yield confident constraint.
|
|
|
|
|
|
#### Millilensing New Testing Set
|
|
|
|
|
|
After additional bugs were squashed, it was identified that the testing set may be simply insufficiently strong to allow detection. A more "obvious" test has been run below yieleding the following results
|
|
|
|
|
|
| Injection Model | Analysis Model | Run Directory | Corner Plot | Sign Off (Suvodip) | Sign Off (Harsh) |
|
|
|
| --------------- | -------------- | ------------- | ----------- | ------------------ | ---------------- |
|
|
|
| Milli | Milli | UWM:`/home/mick.wright/gravelamps-o4-review/new-testing-set/milli-as-milli` | [Corner](https://ldas-jobs.ligo.caltech.edu/~mick.wright/gravelamps-o4-review/new-milli-as-milli.png) | | |
|
|
|
| Milli | Micro | UWM:`/home/mick.wright/gravelamps-o4-review/new-testing-set/milli-as-micro` | [Corner](https://ldas-jobs.ligo.caltech.edu/~mick.wright/gravelamps-o4-review/new-milli-as-micro.png) | | |
|
|
|
| Milli | Unlensed | UWM:`/home/mick.wright/gravelamps-o4-review/new-testing-set/milli-as-unlensed` | [Corner](https://ldas-jobs.ligo.caltech.edu/~mick.wright/gravelamps-o4-review/new-milli-as-unlensed.png) | | |
|
|
|
|
|
|
This leads to log Bayes factors favouring the millilensing model of 362.75 over the microlensing model and 435.72 over the unlensed model, also meaning a favouring of the microlensing model of 72.97 which would again indicate the validity of using the point mass microlensing model as the initial sweep.
|
|
|
|
|
|
### Candidate O4 Sampling Review Tests
|
|
|
|
|
|
These runs use the configuration from the microlensing true run with the candidate sampler settings from the O4 Sampler Review.
|
... | ... | |