... | ... | @@ -105,6 +105,8 @@ After additional bugs were squashed, it was identified that the testing set may |
|
|
| Milli | Micro | UWM:`/home/mick.wright/gravelamps-o4-review/new-testing-set/milli-as-micro` | [Corner](https://ldas-jobs.ligo.caltech.edu/~mick.wright/gravelamps-o4-review/new-milli-as-micro.png) | | |
|
|
|
| Milli | Unlensed | UWM:`/home/mick.wright/gravelamps-o4-review/new-testing-set/milli-as-unlensed` | [Corner](https://ldas-jobs.ligo.caltech.edu/~mick.wright/gravelamps-o4-review/new-milli-as-unlensed.png) | | |
|
|
|
|
|
|
Parameter recovery is significantly improved from before, with support for the true values of all parameters in the posteriors. Individual phases are not distinctly recovered, but results would indicate that the relative phase difference would be recovered correctly.
|
|
|
|
|
|
This leads to log Bayes factors favouring the millilensing model of 362.75 over the microlensing model and 435.72 over the unlensed model, also meaning a favouring of the microlensing model of 72.97 which would again indicate the validity of using the point mass microlensing model as the initial sweep.
|
|
|
|
|
|
### Candidate O4 Sampling Review Tests
|
... | ... | |