|
|
Main results review page: https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results
|
|
|
|
|
|
|No.| NAME | Comments on config ini file|Comments on results from the reviewer | Reviewees comments |
|
|
|
|---| ---- | ---- | ---- | --- |
|
|
|
|1. |[GW190408a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190408a)| Prod0 |<br> Anuradha:<br>BBH run: In think there is a typo in labeling, it should be BBH not ks_pos.<br> ks_pos/ks_sym: The logL is different. S1z and S2z are broader than BBH run, and hence effective spin is broader than BBH run. Mtotal and Mc are shifted towards lower values. <br> <br> Archisman: looks fine. |<br> Difference in SNR and logL are expected. [Discussion on matter-most](https://chat.ligo.org/ligo/pl/n1rhn8sdt7g89muqe45iumdixa)|
|
|
|
|2. |[GW190412m](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190412m)||<br> Anuradha: <br> BBH run: Why log L is so different?<br>ks_pos: Why log L is so different? cos(alpha) is very different. chi_eff, q and Mc have shifted towards lower values. Mtotal and m1 are railing at the lower side. <br>ks_sym: Why log L is so different? Mtotal and m1 are railing at the lower side. q has shifted to higher values. <br> <br> Archisman: needs rerun with wider mtot prior.| <br> Krishnendu:<br> reruns are started|
|
|
|
|No.| NAME | Comments on config ini file|Comments on results from the reviewer | Reviewees comments |Details of the rerun|
|
|
|
|---| ---- | ---- | ---- | --- |--- |
|
|
|
|1. |[GW190408a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190408a)| Prod0 |<br> Anuradha:<br>BBH run: In think there is a typo in labeling, it should be BBH not ks_pos.<br> ks_pos/ks_sym: The logL is different. S1z and S2z are broader than BBH run, and hence effective spin is broader than BBH run. Mtotal and Mc are shifted towards lower values. <br> <br> Archisman: looks fine. |<br> Difference in SNR and logL are expected. [Discussion on matter-most](https://chat.ligo.org/ligo/pl/n1rhn8sdt7g89muqe45iumdixa)||
|
|
|
|2. |[GW190412m](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190412m)||<br> Anuradha: <br> BBH run: Why log L is so different?<br>ks_pos: Why log L is so different? cos(alpha) is very different. chi_eff, q and Mc have shifted towards lower values. Mtotal and m1 are railing at the lower side. <br>ks_sym: Why log L is so different? Mtotal and m1 are railing at the lower side. q has shifted to higher values. <br> <br> Archisman: needs rerun with wider mtot prior.| <br> Krishnendu:<br> reruns are started||
|
|
|
|3. |[GW190425z](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190425z)|| Archisman: still running ||
|
|
|
|4.|[GW190512b](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190512at)||<br> <br> Anuradha: BBH: Why log L is different? <br> <br> Archisman: whys is t0 different? Is the BH run used for comparison a non-spinning run? <br> <br> Archisman (following Krishnendu's first comment): This looks better, thanksT There is a minor mtot railing. We need to decide what to do for runs such as these. | <br> Krishnendu <br> Yes, this is now being addressed. I used Prod4 results for comparison and which was a non-spinning run. Now it is fixed.|
|
|
|
|5.|[GW190521r](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190412m) | Prod0 | <br>Anuradha:<br> BBH: Why log L is different? <br> ks_pos: Why log L is different? q is shifted toward lower side. 1D ks plot is missing on the posplots.html page. <br> ks_sym: Why log L is different? 1D ks plot is missing on the posplots.html page. <br> <br> Archisman: Spins and spin angles are different (expected). Looks good. ||
|
|
|
|6.|[GW190630a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190630ag)||<br>Anuradha: <br>BBH: Why is log L different? <br> ks_pos: Why is log L different? a1, a2 and chi_eff are less constrained. <br> Why is log L different? <br> <br> Archisman: where are the comparison pages? I could not find them. <br> <br> Archisman: Sorry, I still cannot find the comparison plots. I get to the following summary page, but I do not see any plot: https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190630ag/pv2_c01_prod/comp_PE_Prod0/bh_ks_pos/home.html <br> <br> Is there an old-school post-processing page for an SIWM run for this event? |<br> Krishnendu <br> <br> Please see this page for [PE results](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190630ag/pv2_c01_prod/) and [here](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190630ag/pv2_c01_prod/comp_PE_Prod0/) are the comparison page with PE Prod runs|
|
|
|
|7.|[GW190707a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190707q)||<br> Anuradha: All the comparison pages have 'Prod0' vs 'Prod4' legends, so I am not sure if I am looking are correct plots. But I do see evidence for Mtot posterior trailing [here](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190707q/pv2_c01_prod/comp_PE_Prod0/bh_ks_pos/html/Comparison_All.html) <br> <br> Archisman: same question as Anuradha above. Also prod 4 seems to be an aligned spin run. Something rails against the mtot bound, but it is not clear what. Also it seems to slightly fall off near the bound, doesn't it? <br> <br> Archisman: Thanks the comparison page seems fixed! Both the PE and the SIQM run neem to be railing against the prior, but on closer inspection, it seems more likely that the posterior falls off just near the prior edge. The behaviour is clearer on the source frame plot. I am happy to sign this off -- are the other reviewers fine with it? | <br> Krishnendu: <br> <br> Not sure if we need a rerun for this event or not. <br> Base config is the Prod0 ini and there are [no open issues](https://git.ligo.org/search?utf8=%E2%9C%93&snippets=&scope=issues&repository_ref=&search=S190707q&project_id=3816&button=) with this event <br>[bh-comparison page with the Prod results](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190707q/pv2_c01_prod/comp_PE_Prod0_cbcBayesCompPos/bh_bh/) <br><br> Issues regarding the comparison pages are fixed now. <br> Krishnendu: Not hitting the prior boundary [mtotal](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190707q/pv2_c01_prod/pos/ks/1246527224.18-0/H1L1/1Dpdf/mtotal.pdf) and [mtotal_source](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190707q/pv2_c01_prod/pos/ks/1246527224.18-0/H1L1/1Dpdf/mtotal_source.pdf)|
|
|
|
|8.|[GW190708a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190708ap) ||<br> Anuradha: <br> BBH: Why log L, a1, a1z, and a2z are different? <br>ks_pos: a1z, and a2z are different. a1, a2 are totally unconstrained. 1D ks plot is missing on the posplots.html page. <br> ks_sym: a1z, a2z, a1, a2 are unconstrained. 1D ks plot is missing on the posplots.html page. <br> <br> Archisman: spins are significantly different. Why are spins estimated better for the SIQM run than for the PE run? Otherwise fine. In particular, no mtot railing. ||
|
|
|
|9.|[GW190720a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190720a)||<br> Anuradha: There is one comparison page given, the label says 'BH comparison page' but when you go inside it has BH and ks_sym legends. So, I am not sure what am I looking at. Since there are no comparison plots, I am not sure if the results are alright. <br> There are evidence for Mtot posterior trailing [here](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190720a/pv2_prod_c01/comp_ks_bh/) and [here](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190720a/pv2_c01_prod/sym/ks/1247616534.7-0/V1H1L1/posplots.html) <br> <br> Archisman: Spins and spin angles are different (expected). Why is chirp mass so different? There is a minor railing of mtot against the prior. <br> <br> Archisman: This looks fine to me now. Chirp mass is fine. No mtot railing. |<br> <br> Posteriors not hitting the prior boundary[mtotal_det](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190720a/pv2_c01_prod/sym/ks/1247616534.7-0/V1H1L1/1Dpdf/mtotal.pdf) <bt> [mtotal_source](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190720a/pv2_c01_prod/sym/ks/1247616534.7-0/V1H1L1/1Dpdf/mtotal_source.pdf) |
|
|
|
|4.|[GW190512b](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190512at)||<br> <br> Anuradha: BBH: Why log L is different? <br> <br> Archisman: whys is t0 different? Is the BH run used for comparison a non-spinning run? <br> <br> Archisman (following Krishnendu's first comment): This looks better, thanksT There is a minor mtot railing. We need to decide what to do for runs such as these. | <br> Krishnendu <br> Yes, this is now being addressed. I used Prod4 results for comparison and which was a non-spinning run. Now it is fixed.|No rerun|
|
|
|
|5.|[GW190521r](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190412m) | Prod0 | <br>Anuradha:<br> BBH: Why log L is different? <br> ks_pos: Why log L is different? q is shifted toward lower side. 1D ks plot is missing on the posplots.html page. <br> ks_sym: Why log L is different? 1D ks plot is missing on the posplots.html page. <br> <br> Archisman: Spins and spin angles are different (expected). Looks good. ||No rerun|
|
|
|
|6.|[GW190630a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190630ag)||<br>Anuradha: <br>BBH: Why is log L different? <br> ks_pos: Why is log L different? a1, a2 and chi_eff are less constrained. <br> Why is log L different? <br> <br> Archisman: where are the comparison pages? I could not find them. <br> <br> Archisman: Sorry, I still cannot find the comparison plots. I get to the following summary page, but I do not see any plot: https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190630ag/pv2_c01_prod/comp_PE_Prod0/bh_ks_pos/home.html <br> <br> Is there an old-school post-processing page for an SIWM run for this event? |<br> Krishnendu <br> <br> Please see this page for [PE results](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190630ag/pv2_c01_prod/) and [here](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190630ag/pv2_c01_prod/comp_PE_Prod0/) are the comparison page with PE Prod runs|Waiting for comments|
|
|
|
|7.|[GW190707a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190707q)||<br> Anuradha: All the comparison pages have 'Prod0' vs 'Prod4' legends, so I am not sure if I am looking are correct plots. But I do see evidence for Mtot posterior trailing [here](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190707q/pv2_c01_prod/comp_PE_Prod0/bh_ks_pos/html/Comparison_All.html) <br> <br> Archisman: same question as Anuradha above. Also prod 4 seems to be an aligned spin run. Something rails against the mtot bound, but it is not clear what. Also it seems to slightly fall off near the bound, doesn't it? <br> <br> Archisman: Thanks the comparison page seems fixed! Both the PE and the SIQM run neem to be railing against the prior, but on closer inspection, it seems more likely that the posterior falls off just near the prior edge. The behavior is clearer on the source frame plot. I am happy to sign this off -- are the other reviewers fine with it? | <br> Krishnendu: <br> <br> Not sure if we need a rerun for this event or not. <br> Base config is the Prod0 ini and there are [no open issues](https://git.ligo.org/search?utf8=%E2%9C%93&snippets=&scope=issues&repository_ref=&search=S190707q&project_id=3816&button=) with this event <br>[bh-comparison page with the Prod results](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190707q/pv2_c01_prod/comp_PE_Prod0_cbcBayesCompPos/bh_bh/) <br><br> Issues regarding the comparison pages are fixed now. <br> Krishnendu: Not hitting the prior boundary [mtotal](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190707q/pv2_c01_prod/pos/ks/1246527224.18-0/H1L1/1Dpdf/mtotal.pdf) and [mtotal_source](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190707q/pv2_c01_prod/pos/ks/1246527224.18-0/H1L1/1Dpdf/mtotal_source.pdf)|No rerun|
|
|
|
|8.|[GW190708a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190708ap) ||<br> Anuradha: <br> BBH: Why log L, a1, a1z, and a2z are different? <br>ks_pos: a1z, and a2z are different. a1, a2 are totally unconstrained. 1D ks plot is missing on the posplots.html page. <br> ks_sym: a1z, a2z, a1, a2 are unconstrained. 1D ks plot is missing on the posplots.html page. <br> <br> Archisman: spins are significantly different. Why are spins estimated better for the SIQM run than for the PE run? Otherwise fine. In particular, no mtot railing. ||No rerun|
|
|
|
|9.|[GW190720a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190720a)||<br> Anuradha: There is one comparison page given, the label says 'BH comparison page' but when you go inside it has BH and ks_sym legends. So, I am not sure what am I looking at. Since there are no comparison plots, I am not sure if the results are alright. <br> There are evidence for Mtot posterior trailing [here](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190720a/pv2_prod_c01/comp_ks_bh/) and [here](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190720a/pv2_c01_prod/sym/ks/1247616534.7-0/V1H1L1/posplots.html) <br> <br> Archisman: Spins and spin angles are different (expected). Why is chirp mass so different? There is a minor railing of mtot against the prior. <br> <br> Archisman: This looks fine to me now. Chirp mass is fine. No mtot railing. |<br> <br> Posteriors not hitting the prior boundary[mtotal_det](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190720a/pv2_c01_prod/sym/ks/1247616534.7-0/V1H1L1/1Dpdf/mtotal.pdf) <bt> [mtotal_source](https://ldas-jobs.ligo.caltech.edu/~nv.krishnendu/LSC/lalinference/O3/o3_a_tgr/S190720a/pv2_c01_prod/sym/ks/1247616534.7-0/V1H1L1/1Dpdf/mtotal_source.pdf) |Rerun|
|
|
|
|10.|[GW190728a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190728q)|| Archisman: still running ||
|
|
|
|11.|[GW190814a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190814bv) ||<br>Anuradha: No plots, comparison or otherwise, to look at. <br> <br> Archisman: where are the comparison pages? |Please see the updated wiki page|
|
|
|
|12.|[GW190828a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190828j) ||<br> Anuradha: BBH: All parameters are different. You BBH runs is actually better. Prod results are bad, why? <br> ks_pos: Since Prod results are bad, I can not compare. 1D ks plot is missing on the posplots.html page. <br> ks_sym: Since Prod results are bad, I can not compare. 1D ks plot is missing on the posplots.html page. ||
|
|
|
|13.|[GW190924a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190924h)||<br> Anuradha: <br> BBH: m1 and mtotal are railing at the boundary. <br>ks_pos: I hope it is a typo, it says BBH vs PE run. m1, m2 and mtotal are railing at the boundary. 1D ks plot is missing on the posplots.html page. <br> ks_sym: mtotal is railing at the boundary. 1D ks plot is missing on the posplots.html page. <br> <br> Archisman: is the PE run used for comparison a production PE run? PE run seems to have very restrictive distance priors. Why is everything estimated better for the SIQM run then for the PE run? PE run shows mtot railing. SIQM run shows a very marginal mtot railing. ||
|
|
|
|11.|[GW190814a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190814bv) ||<br>Anuradha: No plots, comparison or otherwise, to look at. <br> <br> Archisman: where are the comparison pages? |Please see the updated wiki page|Waiting for comments|
|
|
|
|12.|[GW190828a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190828j) ||<br> Anuradha: BBH: All parameters are different. You BBH runs is actually better. Prod results are bad, why? <br> ks_pos: Since Prod results are bad, I can not compare. 1D ks plot is missing on the posplots.html page. <br> ks_sym: Since Prod results are bad, I can not compare. 1D ks plot is missing on the posplots.html page. ||Rerun|
|
|
|
|13.|[GW190924a](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/S190924h)||<br> Anuradha: <br> BBH: m1 and mtotal are railing at the boundary. <br>ks_pos: I hope it is a typo, it says BBH vs PE run. m1, m2 and mtotal are railing at the boundary. 1D ks plot is missing on the posplots.html page. <br> ks_sym: mtotal is railing at the boundary. 1D ks plot is missing on the posplots.html page. <br> <br> Archisman: is the PE run used for comparison a production PE run? PE run seems to have very restrictive distance priors. Why is everything estimated better for the SIQM run then for the PE run? PE run shows mtot railing. SIQM run shows a very marginal mtot railing. ||Rerun|
|
|
|
|
|
|
**Details of O1/O2 events**
|
|
|
|
|
|
|
|
|
|No.| NAME | Comments on config ini file|Comments on results | Reviewees comments |
|
|
|
|---| ---- | ---- | ---- | --- |
|
|
|
|1. |[GW150914](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW150914) | |<br>Anuradha: No comparison-with-prod-run-plots, no ks plots.<br> ks_pos/ks_sym: Why is log L different? why a1 and a2 are oppositely unconstrained? Why is optimal (or matched-filter) SNR so different than BBH case?|<br>Krishnendu: Comparison pages added now|
|
|
|
|2. |[GW151226](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW151226) | |<br>Anuradha: No comparison-with-prod-run-plots, no ks plots.<br> ks_pos/ks_sym: Why is log L very very different? why a1 and a2 are totally unconstrained? Why is optimal (or matched-filter) SNR so different than BBH case? Mc, Mtot and m1 are railing at the boundary. <br> <br> Archisman: spin angles are different (generic feature); mtot railing. |<br>Krishnendu: Comparison pages added now|
|
|
|
|3. |[GW170104](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW170104) | |<br>Anuradha: No comparison-with-prod-run-plots, no ks plots. <br> ks_pos: Why is log L different? Why a1 and a2 are totally unconstrained? <br> ks_sym: DL and q go beyond prior limits. Why Mc is so different? <br> <br> Archisman: does distance hit the upper bound or is that just the shape of the posterior? |<br>Krishnendu: Comparison pages added now|
|
|
|
|4. |[GW170608](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW170608) | |<br> Anuradha: <br> BBH: Why log L is different? <br>ks_pos: Why log L is different? a2 is unconstrained. m1, m2 and mtotal are railing at the boundary. 1D ks plot is missing on the posplots.html page. <br>ks_sym: Why log L is different? a2 is unconstrained. m1, m2 and mtotal are railing at the boundary. 1D ks plot is missing on the posplots.html page. <br> <br> Archisman: spin angles are different (generic); mtot severely railing. ||
|
|
|
|5. |[GW170814](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW170814) | |<br>Anuradha: No comparison-with-prod-run-plots, no ks plots.<br> ks_pos/ks_sym: Why a1 and a2 are totally unconstrained? <br> <br> Archisman: spin angles are different (generic); mtot is fine. Why is dL so different? Why are sky angles not estimated in the SIQM run? Was a 2 detector run launched by mistake? |<br>Krishnendu: Comparison pages added now|
|
|
|
|1. |[GW150914](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW150914) | |<br>Anuradha: No comparison-with-prod-run-plots, no ks plots.<br> ks_pos/ks_sym: Why is log L different? why a1 and a2 are oppositely unconstrained? Why is optimal (or matched-filter) SNR so different than BBH case?|<br>Krishnendu: Comparison pages added now|No rerun|
|
|
|
|2. |[GW151226](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW151226) | |<br>Anuradha: No comparison-with-prod-run-plots, no ks plots.<br> ks_pos/ks_sym: Why is log L very very different? why a1 and a2 are totally unconstrained? Why is optimal (or matched-filter) SNR so different than BBH case? Mc, Mtot and m1 are railing at the boundary. <br> <br> Archisman: spin angles are different (generic feature); mtot railing. |<br>Krishnendu: Comparison pages added now|Rerun|
|
|
|
|3. |[GW170104](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW170104) | |<br>Anuradha: No comparison-with-prod-run-plots, no ks plots. <br> ks_pos: Why is log L different? Why a1 and a2 are totally unconstrained? <br> ks_sym: DL and q go beyond prior limits. Why Mc is so different? <br> <br> Archisman: does distance hit the upper bound or is that just the shape of the posterior? |<br>Krishnendu: Comparison pages added now|Rerun|
|
|
|
|4. |[GW170608](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW170608) | |<br> Anuradha: <br> BBH: Why log L is different? <br>ks_pos: Why log L is different? a2 is unconstrained. m1, m2 and mtotal are railing at the boundary. 1D ks plot is missing on the posplots.html page. <br>ks_sym: Why log L is different? a2 is unconstrained. m1, m2 and mtotal are railing at the boundary. 1D ks plot is missing on the posplots.html page. <br> <br> Archisman: spin angles are different (generic); mtot severely railing. ||Rerun|
|
|
|
|5. |[GW170814](https://git.ligo.org/nv.krishnendu/lalsuite/-/wikis/O3a-Spin-Quadrupole-BH-mimicker-test-results/GW170814) | |<br>Anuradha: No comparison-with-prod-run-plots, no ks plots.<br> ks_pos/ks_sym: Why a1 and a2 are totally unconstrained? <br> <br> Archisman: spin angles are different (generic); mtot is fine. Why is dL so different? Why are sky angles not estimated in the SIQM run? Was a 2 detector run launched by mistake? |<br>Krishnendu: Comparison pages added now|No rerun|
|
|
|
|
|
|
|
|
|
**Misc**
|
... | ... | |