      Extensive changes to code variable names in the RCG code. · b1b26272
      Rolf Bork authored
      From the user perspective, key changes are in the model Parameter block settings:
      - An IOP model should now be designaeted with iop_model=1
      	- Previously set by adcMaster=1
      - A user control application should have the adcSlave=1 parameter removed.
      	- If iop_model=1 is not in the Parameter block, then RCG assumes
      	  this is a user control application model.
      - IOP models that send/rcv timing over the Dolphin network
      	- The transmitter model Parameter block needs dolphin_time_xmit=1
      	- A recevier IOP model Parameter block needs dolphin_time_rcvr=1
      b1b26272