RCG oscillator test has slight error
With version 4.2.1~dev1 on X2ATS, the automated oscillator test for the RCG has a slight error above threshold for all three frequencies.
Version 4.2.0 is giving a slight error on only the highest frequency when built from source:
at 6500 Hz,
Value 6489 is out of spec - +577.3513800 +577.3514400 6.00000000758882e-05