Simplified awg data mbuf handles excitation data streaming from awg to models
Simplified awg data mbuf works for streaming excitation data to models.
AWG data used to be in the mbuf named <model_name> along with test points, epics data and a DAQ info structure.
Data is now passed through <model_name>_awg. The entire mbuf is mapped with the AWG_DATA structure.
There's no longer any need to calculate offsets. Access code is much simpler. Expansion or configuring of the mbuf layout will be straightforward.