Change BAYESTAR low frequency cutoff to 15 Hz
Search pipelines do not report their low frequency cutoffs in a uniform, machine readable way in the coinc.xml files. BAYESTAR has been using a default value of 30 Hz. A mismatch in low frequency cutoff will lead to a systematic bias in luminosity distance.
In O3, search pipelines used the following low frequency cutoffs:
Pipeline | Cutoff |
---|---|
gstlal (full bandwidth, stellar mass) | 15 Hz |
gstlal (full bandwidth, IMBH) | 10 Hz |
gstlal (early warning) | 10 Hz |
SPIIR | 15 Hz |
PyCBC | 18-30 Hz depending on template |
MBTA (BNS) | 25 Hz |
MBTA (NSBH) | 23 Hz |
MBTA (BBH) | 21 Hz |
15 Hz is a compromise value that is closer to what the pipelines
actually use. A complete solution would be to add an f_lower
column to the sngl_inspiral
table so that pipelines can report
their low frequency cutoffs.
Shikata ga nai.
Edited by Leo P. Singer