Skip to content
Snippets Groups Projects
Commit e4c9c9c8 authored by Jameson Rollins's avatar Jameson Rollins
Browse files

Merge branch '52-beam-spot-sizes-are-wrong-for-advanced-ligo' into 'master'

Correct test mass RoCs in aLIGO ifo.yaml

See merge request !91
parents 5958ec45 536c9366
No related branches found
No related tags found
1 merge request!91Correct test mass RoCs in aLIGO ifo.yaml
Pipeline #128068 passed
......@@ -268,6 +268,6 @@ Optics:
CavityLength: 55 # m, ITM to SRM distance
Tunephase: 0.0 # SEC tuning
Curvature: # ROC
ITM: 1970
ETM: 2192
Curvature: # RoCs per E080511, E080512
ITM: 1934
ETM: 2245
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment